INOR · Temperature Transmitters

APAQ 130 series

Digital 2-wire transmitters configured wirelessly by NFC from a smartphone. C = head-mounted, R = rail-mounted; separate RTD and TC versions.

PhotoModelMountingInputOutputAccuracyIsolationConfigurationDetails
INOR Transmitter APAQ 130 Head / rail Pt100 / Pt1000; TC 4–20 mA RTD ±0.15%; TC see models Non-isolated App (NFC)
INOR APAQ C130 RTD Head (DIN B) Pt100 / Pt1000 4–20 mA ±0.15% of span Non-isolated App (NFC)
INOR APAQ C130 TC Head (DIN B) TC: B, E, J, K, N, R, S, T 4–20 mA E/J/K/N: ±1 K or ±0.2% of span; B/R/S/T: ±2 K or ±0.2% of span Non-isolated App (NFC)
INOR APAQ R130 RTD DIN rail (35 mm) Pt100 / Pt1000 4–20 mA ±0.15% of span Non-isolated App (NFC)
INOR APAQ R130 TC DIN rail (35 mm) TC: B, E, J, K, N, R, S, T 4–20 mA E/J/K/N: ±1 K or ±0.2% of span; B/R/S/T: ±2 K or ±0.2% of span Non-isolated App (NFC)

MinIPAQ series

Universal, non-isolated 2-wire transmitters. MinIPAQ 230 (C230 / R230) replaces the MinIPAQ-HLP / -L with full compatibility.

PhotoModelMountingInputOutputAccuracyIsolationConfigurationDetails
INOR Transmitter MinIPAQ 230 Head / rail RTD, TC, mV, Ω 4–20 mA ±0.1% of span Non-isolated PC (USB), App (NFC / Bluetooth*)
INOR MinIPAQ C230 Head (DIN B) RTD, TC, mV, Ω 4–20 mA ±0.1% of span Non-isolated PC (USB), App (NFC / Bluetooth*)
INOR MinIPAQ R230 DIN rail (35 mm) RTD, TC, mV, Ω 4–20 mA ±0.1% of span Non-isolated PC (USB), App (NFC / Bluetooth*)
INOR Transmitter MinIPAQ-HLP Head (18.5 mm high) RTD (3-/4-wire), TC (11) 4–20 mA — Non-isolated PC (USB)
INOR Transmitter MinIPAQ-L Head (DIN B) RTD (3-/4-wire), TC (11) 4–20 mA — Non-isolated PC (USB)

* Bluetooth requires the ICON-BT modem.

IPAQ series

Isolated, programmable transmitters: universal input, HART®, dual input and Ex-certified models. C = head-mounted, R = rail-mounted.

PhotoModelMountingInputOutputAccuracyIsolationChannelsCertificatesConfigurationDetails
INOR IPAQ C202 Head (DIN B) Pt100 (3-wire) 4–20 mA ±0.1% of span Non-isolated 1 ATEX, IECEx PC (USB)
INOR IPAQ C310 RTD Head (DIN B) RTD, Ω 4–20 mA ±0.1% of span 1500 VAC 1 — PC (USB), App (NFC / Bluetooth*)
INOR IPAQ C330 Head (DIN B) RTD, TC, mV, Ω 4–20 mA ±0.08% of span 1500 VAC 1 ATEX, IECEx, cFMus PC (USB), App (NFC / Bluetooth*)
INOR IPAQ R330 DIN rail (35 mm) RTD, TC, mV, Ω 4–20 mA ±0.08% of span 1500 VAC 1 ATEX, IECEx, cFMus PC (USB), App (NFC / Bluetooth*)
INOR IPAQ C530 Head (DIN B) RTD, TC, mV, Ω 4–20 mA, HART® 7 ±0.08% of span 1500 VAC 1 ATEX, IECEx, cFMus PC (USB), App (NFC / Bluetooth*), HART DD/DTM
INOR IPAQ R530 DIN rail (35 mm) RTD, TC, mV, Ω 4–20 mA, HART® 7 ±0.08% of span 1500 VAC 1 ATEX, IECEx, cFMus PC (USB), App (NFC / Bluetooth*), HART DD/DTM
INOR IPAQ C520 Head (DIN B) RTD, TC, mV, Ω ×2 4–20 mA, HART® ±0.05% of span 1500 VAC 2 ATEX, IECEx, SIL 2 PC (USB), HART DD/DTM
INOR IPAQ R520 DIN rail (35 mm) RTD, TC, mV, Ω ×2 4–20 mA, HART® ±0.05% of span 1500 VAC 2 ATEX, IECEx, SIL 2 PC (USB), HART DD/DTM
INOR IPAQ R460 6 mm rail (4-wire) RTD, TC, mV, Ω, KTY 0/4–20 mA, 0/2–10 V ±0.1% of span 3000 VAC 1 — DIP switch or PC (USB)

* Bluetooth requires the ICON-BT modem.

OEM202 series

Digital transmitters to build into your own sensors, systems or machines, with customisable form factor and sensor types.

PhotoModelInputConnectionOutputAccuracyPower supplyCustomisableDetails
INOR OEM202P Pt100 / Pt1000 (2-/3-/4-wire) Solder pads 4–20 mA ±0.1% of span 5.0–32.0 VDC PTC, NTC, PtX
INOR OEM202R Pt100 / Pt1000 (2-/3-/4-wire) Solder pads 4–20 mA ±0.1% of span 5.0–32.0 VDC PTC, NTC, PtX
INOR OEM202W Pt100 / Pt1000 (2-/3-/4-wire) Solder pads 4–20 mA ±0.1% of span 5.0–32.0 VDC PTC, NTC, PtX

INOR · Isolation Transmitters

Isolation transmitters

Isolation and conversion of mA / V signals, with fixed or selectable ranges.

PhotoModelInputRangesPower supplyIsolationAccuracyWorking voltageHousingDetails
INOR IsoPAQ-60P Bipolar / unipolar mA, V 144 combinations, zero/span 20–253 VAC/DC 4 kV ±0.1% FS 1000 VAC/DC Standard line
INOR IsoPAQ-51P 0(4)–20 mA Fixed, zero/span 20–253 VAC/DC 4 kV ±0.1% FS 600 VAC/DC Standard line
INOR IsoPAQ-41P 0–20 / 4–20 mA, 0–10 V Fixed ranges 20–253 VAC/DC 4 kV ±0.1% FS 600 VAC/DC Standard line
INOR IsoPAQ-40P 0–20 / 4–20 mA, 0–10 V Calibrated range selection 20–253 VAC/DC 4 kV ±0.1% FS 600 VAC/DC Standard line
INOR IsoPAQ-30P 0–20 / 4–20 mA, 0–10 V Calibrated range selection 20–253 VAC/DC 2.5 kV ±0.3% FS 600 VAC/DC Standard line
INOR IsoPAQ-161P ±20 mA, ±10 mA, ±10 V, ±5 V Fixed ranges 24 VAC/DC 3-port — — —
INOR IsoPAQ-131P 0–20 / 4–20 mA, 0–10 V Fixed ranges 24 VAC/DC 3 kV ±0.1% FS 600 VAC/DC Compact line
INOR IsoPAQ-80S Shunt voltage (bipolar / unipolar) Extensive selection, zero/span 20–253 VAC/DC 4 kV ±0.1% FS 1000 VAC/DC Standard line
INOR IsoPAQ-661 Bipolar / unipolar mA, V DIP calibrated, zero/span Terminals or In-Rail-Bus 3 kV ±0.1% FS 600 VAC/DC 6 mm line
INOR IsoPAQ-641 0/4–20 mA, 0/2–10 V DIP calibrated Terminals or In-Rail-Bus 3 kV ±0.1% FS 600 VAC/DC 6 mm line

Loop-powered isolators

Powered by the input signal, no external supply: isolation of 0(4)–20 mA signals.

PhotoModelChannelsSignalPower supplyIsolationAccuracyWorking voltageHousingDetails
INOR IsoPAQ-611 1 0(4)–20 mA Loop-powered 3 kV ±0.1% FS 600 VAC/DC 6 mm line
INOR IsoPAQ-612 2 0(4)–20 mA Loop-powered 3 kV ±0.1% FS 600 VAC/DC 6 mm line
INOR IsoPAQ-21L 1 0(4)–20 mA Loop-powered 4 kV ±0.1% FS 600 VAC/DC Standard line
INOR IsoPAQ-22L 2 0(4)–20 mA Loop-powered 4 kV ±0.1% FS 600 VAC/DC Standard line
INOR Iso-PAQ-11L 1 0(4)–20 mA Loop-powered Galvanic isolation — — —
INOR Iso-PAQ-12L 2 0(4)–20 mA Loop-powered Galvanic isolation — — —
INOR Iso-PAQ-110L 1 / 2 0(4)–20 mA Loop-powered 2.5 kV ±0.15% FS — Compact line

Repeaters, splitters and power terminal

Powering and isolating transmitters, splitting signals and supplying the In-Rail-Bus.

PhotoModelFunctionSignalHARTIsolationAccuracyWorking voltageHousingDetails
INOR IsoPAQ-610 Repeater power supply (powers + isolates 2/3/4-wire transmitters) 0/4–20 mA ✓ 3 kV ±0.1% FS 600 VAC/DC 6 mm line
INOR IsoPAQ-110R Transmitter repeater (powers + isolates 2-wire transmitters) 4–20 mA ✓ 2.5 kV ±0.1% FS 600 VAC/DC Compact line
INOR IsoPAQ-632 Signal splitter (2 isolated outputs) 0/4–20 mA, 0/1–5 V, 0/2–10 V — 3 kV ±0.1% FS 600 VAC/DC 6 mm line
INOR IsoPAQ-Connect In-Rail-Bus power terminal 2 supply inputs — — — — 6 mm line

INOR · Temperature Indicators

LCD temperature indicators

Loop-powered from 4–20 mA with no external supply; a DIN B transmitter can be built in.

PhotoModelHousingDisplayInputConfigurationProtectionBuilt-in transmitterDetails
INOR LCD-H210 Aluminium connection head (BUZ-HW), M20×1.5 cable entry, M24×1.5 process thread 4-digit LCD, backlit 4–20 mA (-1999…9999) App (NFC) or push-buttons IP65 DIN B transmitter built in
INOR LCD-H300 AL Aluminium field housing, M20 or ½" NPT 4-digit LCD, backlit 4–20 mA (-1999…9999) App (NFC) or push-buttons IP68 DIN B transmitter built in
INOR LCD-H300 SS Stainless steel field housing, M20 or ½" NPT 4-digit LCD, backlit 4–20 mA (-1999…9999) App (NFC) or push-buttons IP68 DIN B transmitter built in
INOR LCD-D100 LCD display module (fits into connection heads) 4-digit LCD, backlit 4–20 mA App (NFC) or push-buttons — —
INOR LCD-W110 Rectangular PC box, 2 × M20 cable glands 4-digit LCD, backlit 4–20 mA App (NFC) or push-buttons — —

INOR · Temperature Sensors

TRA-C compact temperature sensors

Pt100 thin-film element in a stainless steel 1.4404 / 316L body for tight spaces; built-in transmitter optional.

PhotoModelRangeProcess connectionDiameterElementElectrical connectionProtectionDetails
INOR TRA-C10 -50 ~ 200 °C Flange DN25/38, ISO 2852 clamp (hygienic) 6 mm Pt100 thin film M12 IP67
INOR TRA-C20 -50 ~ 200 °C G1/2 6 mm Pt100 thin film EN 175301-803 IP65
INOR TRA-C30 -50 ~ 200 °C G1/2 6 mm Pt100 thin film M12 IP67
INOR TRA-C40 -30 ~ 350 °C Plug-in 3 / 6 mm Pt100 thin film M12 IP67
INOR TRA-C50 -50 ~ 120 °C Screw-in 3 mm Pt100 thin film M12 IP67

Elements to DIN EN 60751; body stainless steel 1.4404 / 316L.

INOR · Alarm Units

Alarm units

DIN-rail alarm units with two relay outputs for temperature and signal monitoring.

PhotoModelInputOutputAccuracyPower supplyIsolationMountingDetails
INOR SR336 RTD / resistance 0…3 kΩ 2 × relay, 250 VAC / 6 A 0.2% of span 24 VDC 4000 VAC DIN rail
INOR SR361 0(4)–20 mA / 0–10 V 2 × relay, 250 VAC / 6 A 0.2% of span 24 VDC 4000 VAC DIN rail

INOR · Accessories

Accessories

Configuration tools, software and adapters for INOR transmitters.

PhotoModelUseConnectionIsolationForDetails
INOR Adapter mA Shunt adapter, mA to mV Plugs onto input connector; -1…+100 mA in, 4–20 mA out 1500 VAC IPAQ R330
INOR ICON-BT Bluetooth® modem for remote configuration and monitoring Bluetooth® (71 × 28 × 24 mm) — IPAQ 330, IPAQ 530
INOR ICON-X Ex-certified configuration kit USB (ConSoft) 1500 VAC; ATEX, IECEx, cFMus INOR PC-programmable transmitters
INOR INOR-SET Configuration kit (software + USB converter) USB 4000 VAC IPAQ R460 and 6 mm transmitters
DOWNLOADS

Downloads

  • INOR product overview 2025

    INOR temperature transmitters, isolators, indicators, sensors and accessories.

    PDF · 3.9 MB
    Download PDF

Can't find an exact match?

Tell us your temperature range, mounting and dimensions and our engineers will design it for you.

Open PDF